Publication date: Available online 12 November 2016
Source:Journal of Biomechanics
Author(s): Oren M. Rotman, Uri Zaretsky, Avraham Shitzer, Shmuel Einav
Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from pressure measurement system. The investigation was performed using numerical fluid-structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to Fractional Flow Reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2fJ2b8B
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Introduction Crisis management is a critical organizational function. Failure can result in serious harm to stakeholders, losses for an orga...
-
Publication date: 1 July 2017 Source: Cancer Letters, Volume 397 Author(s): Makoto Sano, Yoshimi Ichimaru, Masahiro Kurita, Emiko Hayashi,...
-
Maritime Logistics • General Ship Knowledge • Seaborne Cargoes and Dangerous Goods • Cargo Planning • Marine Terminal Operations • Modal and...
-
136 Unit 6 • Cause-Effect Essays What is a great topic for a cause-effect essay? This type of essay may focus more on the causes or more on ...
-
Winners of the 13th Annual 2017 Info Security PG's Global Excellence Awards® from #AlexandrosSfakianakis via Alexandros G.Sfakianakis ...
-
Apply to 39 Fifth Third Bank Personal Banker jobs in United States on LinkedIn. Sign-up today, leverage your professional network, and get h...
-
Publication date: Available online 7 April 2017 Source: Experimental Cell Research Author(s): Guoxing Li, Huiyang Song, Weihua Yang, Shans...
-
918 quotes have been tagged as self-confidence: Edgar Allan Poe: ‘I have great faith in fools - self-confidence my friends will call it.’, R...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου