This paper discusses properties of Hall effect sensors with only three terminals and compares them to conventional four-terminal devices. It covers both Horizontal and Vertical Hall effect devices. Their Hall-geometry factor is computed analytically. Several modes of operation are proposed and their signal-to-noise ratio is compared. A six-phase offset cancellation scheme is developed. All theoretical results are checked by measurements. The residual offset of Vertical Hall effect devices with three contacts is found to be smaller than the offset of conventional Vertical Hall effect devices with five contacts.