Publication date: January 2018
Source:European Journal of Radiology, Volume 98
Author(s): Hyungwoo Ahn, Kyung Won Lee, Kyung Hee Lee, Jihang Kim, Kwhanmien Kim, Jin-Haeng Chung, Choon-Taek Lee
PurposeTo assess the effect of window settings and reconstruction plane on clinical T-stage determined by solid portion size within subsolid nodules (SSNs), based on 8th-edition TNM standards.Materials and methodsThis retrospective study included 247 SSNs from 221 patients who underwent surgery for lung adenocarcinomas between Feb 2012 and Oct 2015. Two radiologists independently measured the diameter of the solid portion on axial, coronal, and sagittal planes using lung- and mediastinal-window. The largest diameter among the measurements on the three planes was referred to as multiplanar measurement. Inter-reader agreement as well as the correlation between the CT and pathologic measurements were calculated using intra-class correlation coefficients (ICCs). The proportions of disagreement in clinical T-stage on different measurement methods were measured. The κ values for agreement between clinical- and pathological T-stage were measured.ResultsInter-reader agreement was moderate-to-excellent (ICC confidence interval [CI] range, 0.51–0.92) in lung-window, while it was good-to-excellent (0.77–0.95) in mediastinal-window. The correlation between the CT and pathologic measurements was good-to-excellent (ICC CI range, 0.63–0.82) in lung-window and fair-to-good (0.25–0.78) in mediastinal-window. The proportions of disagreement between clinical T-stages using mediastinal- and lung-window were 32.0%–41.7% and 33.6%–49.0% with axial and multiplanar measurement, respectively. Multiplanar measurement resulted in upstaging in 12.6%–15.8% and 19.0%–24.3% of cases with mediastinal- and lung-window, respectively, when compared with axial measurement alone. The κ values for agreement between clinical T-stage and pathological T-stage ranged from 0.53 to 0.69.ConclusionsMediastinal-window was a more stable method in the aspect of the inter-reader agreement, but the correlation between the CT and pathologic measurement was better in lung-window. The clinical T-stage varied in up to one-half of the cases according to the window setting, and multiplanar measurement resulted in upstaging in up to one-fourth of the cases.
from Imaging via alkiviadis.1961 on Inoreader http://ift.tt/2iKUwgb
Κυριακή 3 Δεκεμβρίου 2017
Effect of computed tomography window settings and reconstruction plane on 8th edition T-stage classification in patients with lung adenocarcinoma manifesting as a subsolid nodule
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-...
-
by Rebekah L. Rogers, Ling Shao, Kevin R. Thornton One common hypothesis to explain the impacts of tandem duplications is that whole gene ...
-
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2juls25 via IFTTT
-
by Qi Quan, Lei Hong, Biao Chang, Ruoxi Liu, Yun Zhu, Jiang Peng, Qing Zhao, Shibi Lu Purpose The purpose of this study was to simulate and...
-
A critical step in cellular-trafficking pathways is the budding of membranes by protein coats, which recent experiments have demonstrated ca...
-
by Mark A. Valasek, Irene Thung, Esha Gollapalle, Alexey A. Hodkoff, Kaitlyn J. Kelly, Joel M. Baumgartner, Vera Vavinskaya, Grace Y. Lin, A...
-
The secondary channel (SC) of multisubunit RNA polymerases (RNAPs) allows access to the active site and is a nexus for the regulation of tra...
-
A phase 1 dose-escalation and expansion study of binimetinib (MEK162), a potent and selective oral MEK1/2 inhibitor British Journal of Canc...
-
ACS Nano DOI: 10.1021/acsnano.6b06114 from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2kOsUGq via...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου