An RFID tag with energy harvesting and sensing capabilities is presented in this paper. This RFID tag is based on an integrated circuit (SL900A) that incorporates a sensor front-end interface capable of measuring voltages, currents, resistances, and capacitances. The aim of this work is to improve the communication distance from the reader to the tag using energy harvesting techniques. Once the energy source and harvester are chosen according to the environment of work, the conditioning circuit for energy management has to be appropriately designed with respect to the nature of the transductor. As a proof of concept, a photovoltaic panel is used in this work to collect the energy from the environment that is managed by a DC-DC converter and stored in a capacitor acting as battery. Such energy is used to support the power system of the tag, giving autonomy to the device and allowing data logging. In particular, the developed tag monitors the ambient temperature and the power voltage. It would be possible to add external sensors without changing the architecture. An increase in the read range of more than 200% is demonstrated. This feature is especially interesting in environments where the access could be difficult.
from #AlexandrosSfakianakis via Alexandros G.Sfakianakis on Inoreader http://ift.tt/2qRQLoR
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δημοφιλείς αναρτήσεις
-
Papillary squamous cell carcinoma of the palatine tonsil: a rare cancer of the head and neck. Acta Otorhinolaryngol Ital. 2017 May 22;...
-
Purpose. To evaluate the diagnostic performance of the McMonnies questionnaire as a screening survey for dry eye in Chinese outpatients. Met...
-
Abstract Background With the development of emergency and intensive medical technologies, the survival rate of traumatic brain injury ha...
-
Background: Paget disease, Bowen disease, and malignant melanoma in situ are intraepidermal neoplasms, characterized by the presence of page...
-
Abstract Blinatumomab is a bispecific T-cell engaging αCD19 antibody used in refractory or relapsed B-cell precursor acute lymphoblastic l...
-
Malignant peripheral nerve sheath tumor (MPNST) is the leading cause of mortality in patients with neurofibromatosis type 1. In 2002, an MPN...
-
We present a case of a patient with diabetes with a pleural empyema originated from a pyomyositis process established after a central line p...
-
Facial plast Surg 2016; 32: 638-645 DOI: 10.1055/s-0036-1597144 After hump removal in reduction rhinoplasty, one of the main steps is to ...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου